EDI
API DocsTerminal

N12 Equipment Environment

To describe the operating environment of the equipment

Sequence
Element
Name
Type
Requirement
Min
Max
Repeat
01
829
Fuel Type Code
Identifier (ID)
Mandatory
1
1
1
Code identifying type of fuel
Codes (21)
02
Composite Unit of Measure
Composite (composite)
Mandatory
1
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Codes (925)
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference and Mapping Guides are provided for marketing purposes and are free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference and Mapping Guides are provided for marketing purposes and are free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.